Liquid cooling solutions
Hands-on installation, commissioning and maintenance for liquid-cooled racks. From rear-door heat exchangers to direct-to-chip cooling for GPU clusters, our engineers fit, test and support the hardware that keeps high-density compute running.
Scope of the service
Every task runs through our 24×7 support desk and closes with photos, logs and notes on the ticket.
Installation
Fitting cooling hardware at the rack.
- Coolant distribution unit (CDU) installation
- Manifolds & quick-disconnect hoses
- Rear-door heat exchangers
- Direct-to-chip cold plate fitting
Commissioning & testing
Proven before the load goes on.
- Fill, flush & pressure testing
- Leak detection checks
- Flow & temperature validation
- Handover documentation
Ongoing support
Keeping cooled racks healthy.
- Preventive maintenance & inspections
- Component swaps & RMA handling
- 24×7 break-fix through the support desk
This service is within the scope of our ISO 9001, ISO 14001 and ISO 45001 certified management systems.
View certificatesTypical requests
A few of the situations this service is built for.
A GPU cluster needs liquid cooling
We install CDUs, manifolds and hoses alongside the rack build, then pressure test before power-on.
Racks run hotter than air can handle
Rear-door heat exchangers add cooling capacity at the rack without reworking the whole room.
A leak alarm in the middle of the night
The 24×7 support desk dispatches an engineer to inspect, isolate and report back with photos.
Frequently asked
Can't find your answer? The support desk is available 24×7.
Ask the support deskWhich liquid cooling equipment do you work with?
Our engineers install and maintain the vendor equipment you specify, including CDUs, rear-door heat exchangers and direct-to-chip cold plates, following the manufacturer's procedures.
Do you pressure test before handover?
Yes. Systems are filled, flushed and pressure tested, with leak checks and flow and temperature results recorded at handover.
Is this part of your AI infrastructure work?
Often, yes. Liquid cooling usually goes in with GPU and high-density deployments. See AI infrastructure.
Often combined with
Data center containment
Hot and cold aisle containment, installed and sealed so cooling reaches the racks that need it.
Explore containmentDeploy · ValidateDeployment, testing & validation
Rack & stack, cabling and commissioning to global standards, tested and certified before handover.
Explore deployment & testingCoreOperate · SupportRemote & smart hands
Certified engineers on site in 250+ data centers, 24×7, for everything from LED checks to diagnostics.
Explore remote handsNeed hands in a data center?
Tell us the site, the task and the timeline. Our 24×7 support desk will confirm engineer availability and send a quote.
24×7 support desksupport@immixtechnologies.com+60 17 317 1211WhatsApp